Techcon TS350 Glue Dispensing Machine Function Settings
Release Date:2017-07-14
Techcon TS350 Glue Dispensing Machine Function Settings
Manual/glue dispensing cycle setting: 1. Press the "Power" button (1) to turn on the device. 2. Press the "Mode" button (2) until "PURGE dispensing" appears on the monitor. 3. Rotate the pressure adjustment knob (5) until the desired dispensing pressure is displayed 4. After filling the syringe or using pre packaged adhesive, attach the syringe to the receiver head assembly. Ensure that the syringe is fixed in the appropriate position. 5. Connect the insertion end of the receiver head assembly to one of the pneumatic dispensing outlets (6). If vacuum suction is required, rotate the vacuum pressure knob (7) counterclockwise to display the required vacuum pressure. 7. Press the "foot switch" to activate the dispensing cycle. (At this moment, the manual/glue dispensing mode is activated)
Automatic dispensing cycle setting 6.2.1 Program selection 1. Press the settings button (3) until "P:" starts flashing 2. Rotate the program selection button (8) to select the desired program 6.2.2 Time Setting 1. Press the mode button (2) to select the desired time mode 2. Press and release the settings button (3) until the time (:) starts flashing 3. Rotate the time knob (8) to select the desired dispensing time 4. Press the foot pedal switch to start the dispensing cycle
Training mode setting In training mode, as long as the foot switch is pressed down, the device will accumulate time. This helps determine the necessary dispensing time when the dispensing output is unknown. 1. Press the mode button (2) to select the training mode 2. Press and release the setting button (3) until the dispensing time is 0.000S 3. Press the "foot pedal" switch. During this operation, the dispensing time will accumulate continuously. When the dispensing reaches the appropriate amount, release the "foot pedal" switch. 5. Press and hold the "Settings" button (3) for 2 seconds to save data. 6. Press the "Mode" button (2) to switch to "TIMED" mode. At this moment, the dispensing machine is set to repeat this cycle.
Continuous dispensing program settings: TS350/TS355 can store up to 10 independent or continuous dispensing threads. 1. Select the automatic dispensing time in the required program according to steps 6.2 2. Simultaneously press the settings button (3) and power button (1) to start a continuous dispensing program Press and hold the settings button (3) for 2 seconds to save the continuous dispensing program The dispensing machine now saves the continuous dispensing program 4. Press the mode button (2) to exit the continuous dispensing program
Cyclic counter The cycle counter records the number of activated automatic dispensing cycles. The maximum number of cycles that can be recorded is 65535 entries. The number is displayed in the lower right corner of the liquid crystal display (LCD). In order to clear the meter Number, you can simultaneously press and hold the settings button (3) and mode button (2) until the counter reaches "0"
Adjust the dispensing pressure and vacuum pressure display 1. Press and release the setting button (3) until (:) flashes on the dispensing pressure and vacuum pressure 2. Rotate the time knob (8) to select the desired display value